The Spirolab is an advanced all-in-one desktop spirometer offering comprehensive respiratory testing. Featuring high-quality spirometry, optional oximetry, and a user-friendly touchscreen interface, it provides rapid, customizable reporting. With versatile connectivity, large memory, long-lasting battery and EMR/EHR compatibility, this compact device delivers accurate lung function assessment for healthcare professionals in various clinical settings.
FlowMIR-VBMax turbine-filter kits are disposable in their entirety and allow compliance with enhanced infection control procedures.
Learn moreTechnical Specifications | |
---|---|
Size | 220 x 210 x 51 mm (8.7 x 8.3 x 2.0 in) |
Weight | 1,450 g (battery pack included) 3.2 lb |
Sensors | |
Power supply | Ni-MH rechargeable battery pack, 6 elements |
Current Consumption | medium 250 mA |
Backup battery voltage | absent |
Charge Batteries | output voltage=12 V, current=1A, compliant with EN 60601-1 |
Autonomy | ∼10 hours |
Connectivity | USB 2.0, Bluetooth® 5 |
Display | 7 inch colour touchscreen resolution 800x480 pixels LCD |
Keyboard | absent, touchscreen |
Mouthpiece | Ø 30 mm (1.18 inches) |
Type of electrical protection | Internally powered Class II while battery is charging |
Safety level due to shock hazard | Type BF device |
Terms of use | Device for continuous use |
Storage conditions | Temp: MIN -40°C, MAX +60°C Humidity: MIN 10% RH; MAX 95%RH |
Transport conditions | Temp: MIN -40°C, MAX +60°C Humidity: MIN 10% RH; MAX 95%RH |
Operating conditions | Temp: MIN +10°C, MAX +40°C Humidity: MIN 10% RH, MAX 95%RH |
Degree of protection against water penetration | IPX1 |
Spirometry | |
Sensor | two-way digital turbine |
Volume range | 10 L |
Flow range | ±16L/s |
Volume accuracy | ±2.5% or 50mL |
Flow accuracy | ±5% or 200 mL/s |
Dynamic resistance | <0.5 cm H2O/L/s |
Temperature sensor | semiconductor (0-45°C) |
Available tests | FVC, VC, IVC, MVV, PRE-POST |
Measured parameters (Stand-alone mode) | VC, FEV1, FEV1/ FVC, FEV1/VC, PEF, FEF25, FEF50, FEF75, FEF25-75, FEF75-85, ELA, extrapolated Vol, FET, Time to PEF, FEV0.5, FEV0.5/FVC, FEV0.75, FEV0.75/ FVC,FEV2, FEV2/ FVC, FEV3, FEV3/ FVC, FEV6, FEV1/ FEV6, FEV1/PEF, FEV1/FEV0. 5, FIVC, FIV1, FIV1/FIVC, PIF, FIF25, FIF50, FIF75, FEF50/FIF50, VC, IVC, IC, ERV, IRV, Rf, VE, VT, tI, tE, VT/tI, tE/tTOT, MVV (measured), MVV (calculated) |
Measured parameters (With MIR Spiro software) | FVC, FEV1, PEF, FEF75, FEF25-75, FET, FEV1/FVC, FEV6, FEV1/FEV6, FEF25, FEF50, FIVC, FEV1/VC, ELA, MVV(cal), Time to PEF, FEV0.5, FEV0.5/FVC, FEV0.75, FEV0.75/FVC, FEF75-85, Extr. Vol, VC, EVC, IVC, IC, VC, ERV FEV3, FIV1, FIV1/FIVC, PIF, FEV3/FVC, PIF, FEV2, FEV2/FVC, FIF25, FIF50, FIF75, R50, FEV1/PEF (EI), FEV1/FEV0.5 (RFEV), TV, VE, RR, tI |
Memory capacity | more than 10,000 tests |
Oximetry (Optional) | |
Measurement method | Infrared absorption |
SpO2% Range | 0-99% |
Accuracy of SpO2% | ± 2% between 70-99% SpO2% |
Average number of beats for SpO2% calculation | 8 beats |
Cardiac pulse range | 18-300 BPM |
Cardiac pulse accuracy | ± 2BPM or 2% the greater of the two |
Mean interval for calculation of heartbeat | 8 seconds |
Signal quality indication | 0 - 8 segments on screen |
Test available | spot |
Measured parameters | SpO2% (Baseline, Min., Max., Mean), Wrist Rate (Baseline, Min., Max., Mean), T90, T89, T88, T5, Index (12s), SpO2 Events, Write Rate Events (bradycardia, tachycardia), Tot Time, Measured Time |
Memory capacity | about 500 hours of oximetry |