MIR Spirobank II Smart Spirometer for Tablets and PC

Catalog #:330518
Suggested Retail: $1600.00
Sale Price: $1440.00
Add to Cart for Lower Price
$200 Cash Rebate: Email the MIR Spirometer Rebate Form and the purchase invoice dated between Nov. 1 and Dec. 31, 2024 to [email protected]. Applies to U.S. customers only. Last day to submit rebate is January 15, 2025.

Versatile 3-in-1 Functionality

The Spirobank II Smart spirometer offers three modes of use: stand-alone operation, PC connection running MIR Spiro software via USB, and iOS or Android tablet connection running the MIR Spiro app via Bluetooth, providing ultimate flexibility for healthcare professionals.

Comprehensive Spirometry and Oximetry Testing

This device supports a wide range of tests including FVC, VC, MVV, PRE/POST bronchodilator comparison for spirometry, and SpO2% and BPM measurements for optional oximetry.

Enhanced Patient Engagement

With real-time test displays and a pediatric incentive animation available on both Tablet and PC, the Spirobank II Smart improves patient collaboration during testing.

Seamless EMR/EHR Integration

The device integrates with Electronic Medical/Health Records systems through MIR Spiro software and app, supporting various protocols including HL7, GDT, FHIR, and EXCHANGE PROTOCOL.

Long-lasting Performance

Featuring a rechargeable lithium battery and large internal memory capable of storing up to 10,000 spirometric tests or 500 hours of oximetry, the Spirobank II Smart ensures extended use without frequent charging or data transfers.

Compatible Sensors

Disposable Filter-Turbine Kit

FlowMIR VBMax Turbine Filter Kit for MIR Spirometers

FlowMIR-VBMax turbine-filter kits are disposable in their entirety and allow compliance with enhanced infection control procedures.

Learn more

MIR Spirobank II Smart Technical Specifications

Spirometry
Size 55 x 160 x 25 mm (2.2 x 6.3 x 1.0 in)
Weight 140 g (battery pack included) 5 oz.
Turbine
Power supply 3.7 V, 1100 mAh Lithium-Ion Rechargeable
Current Consumption 1100 mAh
~20-30 mA (during testing)
Charge Batteries Voltage=5 V DC
Current = minimum 500 mA
Connector: micro USB type B
Complies with EN 60601-1
Autonomy 50 hours
Connectivity USB 2.0, Bluetooth® 4.0
Display monochrome LCD, 160 x 80 pixels
Keyboard 6-key membrane
Mouthpiece Ø 30 mm (1.18 in)
Type of electrical protection Powered internally
Safety level Electric shock Type BF device
IP protection level IPX1
Terms of use Device for continuous use
Storage conditions Temp: MIN -20°C, MAX+60°C
Humidity: MIN 10% RH; MAX 95%RH
Operating conditions Temp: MIN +10°C, MAX +40°C
Humidity: MIN 10% RH, MAX 95%RH
Transport conditions Temp: MIN -40°C, MAX +70°C
Humidity: MIN 10% RH, MAX 95%RH
Sensor two-way digital turbine
Flow range ±16L/s
Volume accuracy ±2.5% or 50mL
Flow accuracy ±5% or 200 mL/s
Dynamic resistance <0.5 cm H2O/L/s
Temperature sensor semiconductor (0-45°C)
Available tests FVC, VC, IVC, MVV, PRE-POST
Measured parameters (MIR Spiro software via USB) FVC, FEV1, PEF, FEF75, FEF25-75, FET, FEV1/FVC, FEV6, FEV1/FEV6, FEF25, FEF50, FIVC, FEV1/VC, ELA, MVV(cal), Time to PEF, FEV0.5, FEV0.5/FVC, FEV0.75, FEV0.75/FVC, FEF75-85, Extr. Vol, VC, EVC, IVC, IC, VC, ERV FEV3, FIV1, FIV1/FIVC, PIF, FEV3/FVC, PIF, FEV2, FEV2/FVC, FIF25, FIF50, FIF75, R50, FEV1/PEF (EI), FEV1/FEV0.5 (RFEV), TV, VE, RR, tI
Measured parameters (MIR Spiro app via Bluetooth) FVC, FEV1, FEV1%, PEF, ELA, FEF25-75, FET, FEF50*, FIVC*
*Available on Android Tablet only
Measured parameters (Stand-Alone mode) *FVC, *FEV1, *PEF, FVC, FEV1, FEV1/FVC, FEV1/VC, PEF, T-PEF, FEF25-75, FEF75-85, FEF25, FEF50, FEF75, FEV0.5, FEV0.5%, FEV0.75, FEV0.75%, FEV2, FEV2%, FEV3, FEV3/FVC, FEV6, FEV6%, FET, BEV, FIVC, FIV1, FIV1/FIVC, PIF, FIF25, FIF50, FIF75, R50, MVVcal, VC, EVC, IVC, IC, ERV, TV, VE, RR, tI, tE, TV/tI, tI/tTot, MVV, ELA
*Best values
Memory capacity more than 10,000 tests
Oximetry (Optional Module)
Measurement method Red and infrared absorption
SpO2% range 0-99%
Accuracy of SpO2% ± 2% between 70-99% SpO2
Average number of beats for SpO2% calculation 8 beats
Heart Pulse Range 30-300 BPM
Cardiac pulse accuracy ± 2BPM or 2% the greater of the two
Mean interval for calculation of heartbeat 8 seconds
Signal quality indication 0 - 8 segments on screen
Test available spot
Measured parameters SpO2% min, max, average
Min, Max, Avg BPM
Test duration
% Duration of bradycardia (<40 BPM)
% Duration of tachycardia (>120 BPM)
% Time with SpO2 ≤ 90% (T90%, T89%)
Memory capacity about 300 hours of oximetry
Loading...