The Vitalograph Pneumotrac Spirometer with RMS performs full spirometry and measures respiratory muscle strength in one PC-based device. In addition to the full range of spirometry values, the Pneumotrac with RMS measures the maximal inspiratory pressure (MIP), maximal expiratory pressure (MEP), sniff nasal inspiratory pressure (SNIP), and peak cough flow (PCF).
The Pneumotrac with RMS makes it simple to measure MIP, MEP, SNIP in both adults and children. The Pneumotrac with RMS is ideal for assessing diaphragmatic weakness in patients with neuromuscular disease, evaluating respiratory muscle strength in patients in pulmonary rehabilitation, and monitoring the response of respiratory muscle training.
The redesigned Spirotrac 6 software complies with the ATS/ERS Standardization of Spirometry 2019 Update and features an intuitive interface and advanced quality control feedback. Additionally, it is compatible with all major EHR/EMR systems via HL7.
Respiratory Muscle Strength Features
Spirometry Features
Vitalograph Pneumotrac With RMS Specifications | |
---|---|
Vitalograph Pneumotrac with RMS | |
MIP, MEP, SNIP Measurement Range | ± 300 cmH2O |
MIP, MEP, SNIP Accuracy | ± 3% |
Resolution | 0.1 cmH20 |
RMS Test Types | MIP, MEP, SNIP, PCF |
RMS Predicted Sets | Wilson, Stefanutti/Uldry/Fitting |
Spirometry Test Types | VC, FVC, PCF, Post-Bronchodilator |
PEF Accuracy | Within ±10% |
Vitalograph Pneumotrac Spirometer | |
Flow Detection Principal | Fleisch type pneumotachograph |
Volume Detection | Flow integration sampling @ 100 Hz |
Volume Accuracy | Within ±2.5% |
Flow Measurement Range | Max. flow rate 960 L/min (±16 L/s) Min. flow rate 1.2 L/min (±0.02 L/s) |
PEF Accuracy | Within ±10% |
Back pressure | Less than 0.1 kPa/L/sec @ 14L/sec |
Operating temperature range | ISO26782 limits: 17–37 °C Design limits: 10–40 °C |
Operating humidity range | 30%–75% |
Ambient pressure range | 850 hPa–1060 hPa |
Performance standards | the Vitalograph Pneumotrac meets or exceeds ATS/ERS 2019, ISO 23747:2015 & ISO 26782:2009 QA/GMP standards EN ISO 13485, FDA 21 CFR 820, SOR/98-282, JPAL |
Dimensions | 160 mm x 95 mm x 115 mm (6.3 in x 3.7 in x 4.5 in) |
Weight | 550 g (1.21 lbs) |
Power Supply | 5 V DC via USB |
Communications | USB 2.0/3.0 |
Device Classification | Class II (USA) / IIa (EU) medical device |
Vitalograph Spirotrac 6 Software | |
PC Requirements | 2.00 GHz or faster, 4 GB RAM, Microsoft .NET 4.8, SQL Server Express, Windows 10 or higher, USB port, 1200 x 800 monitor. |
Test Types Supported | Spirometry: Single breatd testing, multi-breatd testing, tidal breatding. VC, FVC, PCF, Pre-/Post-Bronchodilator |
FVC Parameters | FVC, FEV1, FEV6, FEV1/FVC, FEV1/FEV6, FEV1 Ratio, PEF (L/s), PEF(L/min), FIVC, PIF (L/s) , PIF (L/min), EF25-75, TV, IRV, ERV, IC, EV, TExt, TPef, FET, FEV.5, FEV.5/FVC, FEV.75, FEV.75/FVC, FEV3, FEV3/FVC, FEV6/FVC, FEF0.2-1.2, FEF75-85, FEF2575/FVC, FEF25, FEF50, FEF75, FEV1/PEF, FIF25, FIF50, FIF75, FIF50/FEF50, FIVC/FVC, FIV1, FEV1/FIVC, FIV1/FIVC, FIV1/FVC, FEF50/FIF50, MVVind, EV/FVC, FMFT, IVC, FEV1/IVC, FEFmax, EOTV , FEV1/HT2, FEV1/VC, FEV3/VC, RAWind, RV, FRC, TLC, Lung Age, EOTV, THes, Rise Time |
VC Parameters | VC, IVC, EVC, TV, IC, ERV, TLC, FRC, RV |
Predicted Values Selectable | GLI (Quanjer 2012), NHANES, ERS 93, Forche |
Suggested Interpretation | ATS/ERS Gold |
Database | MS SQL server |
Device classification | IIa per Annex IX of tde MDD |
EMR Connectivity | HL7, GDT |
Export Options | PDF reports |
Import Options | Spirotrac V Database Migration |
Languages | English |
Incentives | Candles, Ball and Tube, Big Bad Wolf |
Trending | Automatic FEV1 trend. Additional parameters also available. |
Reporting | Comprehensive configurable PDF reports |