Astra BT Handheld Spirometer With AstraPro EMR Software

Regular Price: $1,116.00
On Sale For: $995.00
Catalog #:310150

Astra BT Handheld Spirometer With AstraPro Software

Astra BT is a wireless spirometer functions with two AAA batteries and offers mobility for occupational health professionals as well as for primary care clinics and hospitals. The spirometer comes with the AstraPro software.

Features:

  • Tests: FVC/ Bronchodilation, VC, MVV and bronchoconstriction (+40 parameters).
  • Simultaneous F/V and V/T graphs
  • Multiple incentive graphs
  • Over 20 international references
  • Includes the Quanjer 2012-GLI with LLN and Z-score reference values
  • Trend reports to view the development of the patient
  • Ergonomic handle with connectivity indicator
  • Integrated temperature sensor
  • Power saving mode
  • Transmit and share data and results with your EMR system
  • Meets ATS standards
  • NIOSH-compliant
  • Export data in XML or PDF
  • Compatible with Windows 7, 8.1 and 10

AccuFlo™ Digital Turbine

The AccuFlo™ bidirectional turbine with optoelectronic rotary sensor can be detached for cleaning. Sapphire bearings ensure optimal performance for the life of the turbine. AccuFlo has a unique flow trigger algorithm that allows tidal breathing prior to the patient expiratory effort making the spirometry test easier for the patient and insuring quality test results.

AstraPro™ Software

Choose either pre- and post-bronchodilator and bronchial challenge testing or use the incentive program with your pediatric patients. The Astra BT communicates with AstraPro wirelessly via Bluetooth.

Astra BT Spirometer Specifications
Forced Parameters Measured
Forced vital capacity: FVC, FEV1, FEV1/FVC, PEF, FEF50%, FEV6, FEV1/FEC, PEF, FEF25-75%, FEV6, FEV1/ FEV0.5, PEFT, Vext, FIVC, FIF50%, FEF50/FIF50, QC Grades, FEV3, FEV0.5, FEV0.5/FVC, FEV3/FVC, FEV1/VC, FEV1/FEV6, FEV1/PEF, FEV1/FIV1, PEF/PIF, FEV25%, FEF25%, FEF75%, FEF75-85%, FET25-75%, FET100, FIV1, FIV1/FVC, PIF, MTT, MVV Ind, Lung age
MVV: MVV, Br./min
Bronchoconstriction: FVC, FEV1, PEF, FEF25-75%, PDX
Relaxed Parameters Measured
VC: VC, TV, ERV, IRV, IC, Ti, Te, Tt, Ti/Tt
Maneuvers per patient: 8 Total; Best test and last test highlighted
Interpretation: Kory, Miller, ATS, NLHEP (Ferguson)
Predicted sets: GLI/QUANJER, SEPAR 2013, ERS, KNUDSON, CRAPO, ZAPLETAL, MORRIS, AUSTRIA, GUTIERREZ, CASTRO - PEREIRA 2002, POLGAR-WENG, HANKINSON-NHANES III, PEREZ-PADILLA, A.J. CRUZ GOLSHAN, GARCIA RIO, CANDELA, PLATINO, THAI 2000, CASTRO PEREIRA 2007
Ethnic correction: % Actual, Caucasian, Hispanic, African-American
Language: English, Spanish, French
Measurement Scale (BTPS)
Flow range: 0–16 L/sec
Volume: 0–10 L
Measurement method: Infrared Interruption via Digital Turbine
Dynamic flow resistance: < 1.5 cm H20/L/sec @ 14 L/sec
Measurement Precision (BTPS)
At highest volume: ± 3% or 50 ml
At highest flow: ± 5% or 150 ml
Time related precision: 0.5%
Volume resolution: < 6 mL
Sampling frequency: 100 Hz
Power, Ports, and Dimensions
Batteries 2 Alkaline AAA batteries, or 2 rechargeable AAA batteries
Connectivity: Bluetooth 2.0, USB 2.0, USB 3.0
Weight: 6 oz (173 g)
Dimensions: 7.1 x 3.5 x 2.0 in (18 x 9 x 5 cm)