ndd Easy on-PC Spirometer

Catalog #:320250
Suggested Retail: $2047.00
Sale Price: $1872.75
Add to Cart for Lower Price

ndd Easy on-PC Spirometer for FVC, FVL, SVC, MVV, Provocation

ndd Medical Technologies' Easy on-PC spirometer runs on any device running Microsoft Windows, leveraging its TrueFlow™ technology that delivers unprecedented accuracy and reliable results without needing calibration. Real-time graphs and animated incentive screens enhance the user experience, encouraging child and adult patients to help them achieve optimal results.

Easy on-PC Spirometer features:

  • Real-time curves and pediatric incentives
  • Intuitive PC-based solution
  • Automated user guidance throughout maneuvers based on current ATS/ERS standards
  • Reproducible results ensure comparability in multicenter studies
  • Immediate test quality feedback in accordance with ATS/ERS criteria
  • Integrated provocation test with customizable protocols
  • Z-score, LLN and %predicted for fast interpretation of results
  • Export of pdf files and raw data
  • Flexible HL7, XML, GDT, or API interface for easy EMR/EHR integration
  • Wide range of selectable predictable values including the new GU predicted set
  • Absolute hygienic solution with Spirette consumable eliminates the risk of cross-contamination
  • Customizable reports
  • Powerful data-management, including simple local storage or SQL Server database

What's in the box?

  • Spirometry Sensor
  • Software
  • Carrying Case
  • Windows tablet (pictured above) not included

ndd Easy on-PC Spirometer Specifications

Technical
Printing optionsDirect to printer or over network
Data managementEasyWare Pro (SQLite, MS SQL Server)
InterfaceHL7, XML, GDT
Number of tests> 10,000 tests
Age rangeSpirometry > 4 years
Device classificationType BF applied part
Operating conditionsTemp 0 - 40 °C/ 32 - 104 °F
Rel. Humidity 5 - 95%
Athmosph. Pressure 500 - 1060 hPa
PC/Laptop Requirements
Hard disk capacityInstallation/system 1GB
Data: up to 4GB
RAM2 GB
Operating systemWindows 7, Windows 8 and 8.1 (32 and 64 bit), Windows 10 (32 and 64 Bit)
Parameters
FVCATI, BEV, EOTV, FEF10, FEF25, FEF2575, FEF2575_6, FEF40, FEF50, FEF50/FVC, FEF50/VCmax, FEF60, FEF75, FEF75-85, FEF80, FET, FET25-75, FEV.25, FEV.5, FEV.5/FVC, FEV.75, FEV.75/FEV6, FEV.75/FVC, FEV.75/VCmax, FEV1, FEV1/FEV6, FEV1/FVC, FEV1/FVC6, FEV1/VCmax, FEV1/VCext, FEV3/FVC, FEV3/VCmax, FEV3, FEV6, FVC, FVC6, MEF20,MEF25, MEF40, MEF50, MEF60, MEF75, MEF90, MMEF, MTC1, MTC2, MTC3, MTCR, PEF, PEFT, t0, VCext, VCmax
FVLATI, BEV, CVI, E50/150, EOTV, FEF10. FEF25, FEF2575, FEF2575_6, FEF40, FEF50, FEF50/FVC, FEF50/VCmax, FEF60,FEF75, FEF75-85, FEF80, FET, FET25-75, FEV.25, FEV.5, FEV.5/FVC, FEV.75, FEV.75/FEV6, FEV.75/FVC, FEV.75/VCmax,FEV1, FEV1/FEV6, FEV1/FIV1, FEV1/FVC, FEV1/VCmax, FEV1/VCext, FEV3/FVC, FEV3/VCmax, FEV3, FEV6, FIF25,FIF50, FIF50/FEF50, FIF75, FIV.25, FIV.5, FIV1, FIVC, FVC, MEF20, MEF25, MEF40, MEF50, MEF60, MEF75, MEF90,MIF25, MIF50, MIF75, MMEF, MTC1, MTC2, MTC3, MTCR, PEF, PEFT, PIF, t0, VCext, VCmax
SVCERV, IC, IRV, Rf, VC, VCex, VCext, VCin, VCmax, VT
MVVMVV, MVV6, MVVtime, VT
Predicted Normal Values
GLIStanojevic 2009, Quanjer 2012
North AmericaNHANES III (Hankinson) 1999, Knudson 1983, Knudson 1976, Crapo 1981, Morris 1971 & 1976, Hsu 1979, Dockery (Harvard) 1993, Polgar 1971, Gutierrez (Canada) 2004, Eigen 2001
Latin AmericaPereira 1992, Perreira 2006 & 2008, Pérez-Padilla (PLATINO) 2006, Pérez-Padilla (Mexico) 2001, Pérez-Padilla (Mexico, Pediatrics) 2003, Chile 2010, Chile (Pediatrics) 1997
EuropeERS (ECCS, EGKS, Quanjer) 1993, Zapletal 1977, Zapletal 2003, Rosenthal 1993, Austria 1988, Austria 1994, Sapaldia (Switzerland) 1996, Roca (Spain, SEPAR) 1982, Garcia-Rio (SEPAR) 2013, Vilozni 2005, Falaschetti 2004, Klement (Russia) 1986
Europe ScandinaviaHedenström 1985 & 1986, Gulsvik (Norway) 1985, Berglund Birath (Sweden) 1963, Langhammer (Norway) 2001, Finnish 1982 (1998), Nystad 2002
AustraliaHibbert 1989, Gore Crockett 1995
AsiaChhabra (India) 2014, Dejsomritrutai (Thailand) 2000, Indonesia 1992, IP (China, HongKong) 2000 & 2006, JRS 2001 & 2014
AfricaEthiopia 1985
Flow & Volume Sensor
TypeUltrasonic transit time
Flow Range± 16 L/s
Flow Resolution4 mL/s
Flow Accuracy (except PEF)± 2% or 0.02 L/s
PEF Accuracy± 5% or 0.200 L/s
MVV Accuracy± 5% or 5 L/min
Volume Resolution1 mL
Volume Accuracy± 2% or 0.050 L
Resistance~0.3 cm H20/L/s at 16 L/s
Sample rate400 Hz
Standards & Recommendations
Quality, Medical Devices & ElectricalEN ISO 9001 , EN ISO 13485 , EN ISO 14971 , EN 62366 , EN 62304 , EN ISO 26782 , EN ISO 23747 , IEC 60601-1, IEC 60601-1-2
FDA510(k) clearance
MDD 93/42/EECCE marked
Associations & InstitutesATS/ ERS 2005, NIOSH, OSHA, SSA Disability
Languages
English, French, German, Spanish, Italian, Brazilian-portuguese, Dutch, Russian, Vietnamese, Turkish, Chinese